Precision of electromyography according to the calibration approach of neuromuscular monitoring: a randomised prospective agreement study

dc.contributor.authorScheffenbichler, Flora T.
dc.contributor.authorUlm, Bernhard
dc.contributor.authorBorgstedt, Laura
dc.contributor.authorScholze, Anna
dc.contributor.authorKretsch, Nadine
dc.contributor.authorZia, Nadine
dc.contributor.authorFriedrich, Viola
dc.contributor.authorMarb, Magdalena
dc.contributor.authorSchaller, Stefan J.
dc.contributor.authorJungwirth, Bettina
dc.contributor.authorBlobner, Manfred
dc.date.accessioned2026-11-03T13:10:32Z
dc.date.available2026-11-03T13:10:32Z
dc.date.issued2025-05-28
dc.date.updated2025-10-28T08:19:21Z
dc.description.abstractAbstract Purpose Anaesthesia providers often complain that quantitative neuromuscular monitoring does not accurately assess neuromuscular function, a problem that can be mitigated by appropriate calibration. However, there are only very limited recommendations for the calibration of quantitative neuromuscular monitoring in clinical routine. Therefore, this multicentre prospective agreement study compared the precision of electromyography using three different calibration approaches. Methods Sixty patients were assigned to one of three investigational calibration approaches: calibration before anaesthesia induction, calibration during anaesthesia induction, i.e., at loss of consciousness and state entropy < 85, or uncalibrated. All patients received electromyography calibration under deep anaesthesia on the second arm (control as recommended for research). The primary endpoint was the repeatability coefficient, which describes the fluctuation of the following train-of-four (TOF) reading. It therefore provides an estimate of the precision of a measurement method. Secondary endpoints included agreement with control calibration and pain at induction. Results The repeatability coefficient at TOF ratios ≥ 0.8 indicated that electromyography monitoring was less precise when TOF readings were uncalibrated (0.124 ± 0.130) or with calibration during induction (0.087 ± 0.104) but was acceptable after calibration before induction (0.075 ± 0.036) compared to those measured after calibration on the contralateral arm (control: 0.072 ± 0.027, 0.061 ± 0.021, and 0.083 ± 0.063, respectively). Recall of pain at anaesthesia induction did not differ between investigational groups. Conclusion The findings underline the importance of thoroughly performed calibration for precise TOF readings to reliably exclude residual neuromuscular blockade. Electromyography was most precise when calibration was performed under deep anaesthesia (control). If that approach is not possible in the clinical setting, our data suggest that calibration before anaesthesia induction can be considered if previously discussed with the patient. Clinical trial registration Clinical Trials NCT04911088, registered January 6, 2021.
dc.description.versionpublishedVersion
dc.identifier.doihttps://doi.org/10.18725/OPARU-61599
dc.identifier.urlhttps://oparu.uni-ulm.de/handle/123456789/61674
dc.identifier.urnhttp://nbn-resolving.de/urn:nbn:de:bsz:289-oparu-61674-3
dc.language.isoen
dc.publisherUniversität Ulm
dc.relation.isSupplementedByhttps://link.springer.com/article/10.1007/s10877-025-01304-z#Sec17
dc.relation1.doi10.1007/s10877-025-01304-z
dc.rightsCC BY 4.0 International
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectCalibration
dc.subjectNeuromuscular blockade
dc.subjectNeuromuscular blocking drugs
dc.subjectNeuromuscular monitoring
dc.subjectElectromyography
dc.subject.ddcDDC 610 / Medicine & health
dc.titlePrecision of electromyography according to the calibration approach of neuromuscular monitoring: a randomised prospective agreement study
dc.typeWissenschaftlicher Artikel
source.fromPage1047
source.identifier.eissn1573-2614
source.issue5
source.publisherSpringer
source.titleJournal of Clinical Monitoring and Computing
source.toPage1056
source.volume39
source.year2025
uulm.OAcosts2647,18 / 2026
uulm.affiliationGeneralMedizinische Fakultät
uulm.affiliationSpecificUKU. Klinik für Anästhesiologie und Intensivmedizin
uulm.bibliographieuulm
uulm.categoryPublikationen
uulm.categoryDeepGreenDeposits
uulm.identifier.pubmed40437152
uulm.identifier.wos001498301000001
uulm.peerReviewja
uulm.typeDCMIText
uulm.updateStatusURNurl_update_general

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
10877_2025_Article_1304.pdf
Size:
2.61 MB
Format:
Adobe Portable Document Format

Collections