Precision of electromyography according to the calibration approach of neuromuscular monitoring: a randomised prospective agreement study
Loading...
Date
2025-05-28
Authors
Scheffenbichler, Flora T.
Ulm, Bernhard
Borgstedt, Laura
Scholze, Anna
Kretsch, Nadine
Zia, Nadine
Friedrich, Viola
Marb, Magdalena
Schaller, Stefan J.
Jungwirth, Bettina
Journal Title
Journal ISSN
Volume Title
Publication type
Document version
publishedVersion
Distributor
Universität Ulm
Published in
Journal of Clinical Monitoring and Computing, 2025
Abstract
Abstract
Purpose
Anaesthesia providers often complain that quantitative neuromuscular monitoring does not accurately assess neuromuscular function, a problem that can be mitigated by appropriate calibration. However, there are only very limited recommendations for the calibration of quantitative neuromuscular monitoring in clinical routine. Therefore, this multicentre prospective agreement study compared the precision of electromyography using three different calibration approaches.
Methods
Sixty patients were assigned to one of three investigational calibration approaches: calibration before anaesthesia induction, calibration during anaesthesia induction, i.e., at loss of consciousness and state entropy < 85, or uncalibrated. All patients received electromyography calibration under deep anaesthesia on the second arm (control as recommended for research). The primary endpoint was the repeatability coefficient, which describes the fluctuation of the following train-of-four (TOF) reading. It therefore provides an estimate of the precision of a measurement method. Secondary endpoints included agreement with control calibration and pain at induction.
Results
The repeatability coefficient at TOF ratios ≥ 0.8 indicated that electromyography monitoring was less precise when TOF readings were uncalibrated (0.124 ± 0.130) or with calibration during induction (0.087 ± 0.104) but was acceptable after calibration before induction (0.075 ± 0.036) compared to those measured after calibration on the contralateral arm (control: 0.072 ± 0.027, 0.061 ± 0.021, and 0.083 ± 0.063, respectively). Recall of pain at anaesthesia induction did not differ between investigational groups.
Conclusion
The findings underline the importance of thoroughly performed calibration for precise TOF readings to reliably exclude residual neuromuscular blockade. Electromyography was most precise when calibration was performed under deep anaesthesia (control). If that approach is not possible in the clinical setting, our data suggest that calibration before anaesthesia induction can be considered if previously discussed with the patient.
Clinical trial registration
Clinical Trials NCT04911088, registered January 6, 2021.
Description
Faculties
Medizinische Fakultät
DFG Project uulm
EU Project uulm
Other projects uulm
Citation
Is version of
Has version
Supplement to
Has erratum
Erratum to
Has Part
Part of
DOI external
DOI external
10.1007/s10877-025-01304-z
Institutions
Periodical
Degree Program
DFG Project THU
EU Project THU
Other projects THU
Series
Collections
Endorsement
Review
Supplemented By
Referenced By
Zeitraum:
Creative Commons license
Except where otherwised noted, this item's license is described as CC BY 4.0 International