Eignung der Wirbelsäulen von Kalb, Schwein und Schaf für die In-vitro-Testung von Cages und Pedikelschraubensystemen
Loading...
Date
Authors
Liakos, Lambros
Journal Title
Journal ISSN
Volume Title
Publication type
Document version
Distributor
Universität Ulm
Published in
Abstract
Pre-clinical in vitro tests are needed to evaluate the biomechanical performance of new spinal implants. For such experiments large animal models are frequently used. Whether these models allow any conclusions concerning the implant´s performance in humans is difficult to answer. The aim of the present study was to investigate whether calf, pig or sheep spine specimens may be used to replace human specimens in in vitro flexibility and cyclic loading tests with two different implant types. First, a dynamic and a rigid fixator (tangoRS) were tested using six human, six calf, six pig and six sheep thoracolumbar spine specimens. Standard flexibility tests were carried out in a spine tester in flexion/extension, lateral bending and axial rotation in the intact state, after nucleotomy and after implantation. Then, the Wave-S Cage implant was tested for flexibility and sintering tendency using another six human and six calf lumbar spine segments. Loading was carried out as described above in the intact condition, after creation of a defect and after implantation. The fixators were most easily implantable into the calf. Qualitatively, they had similar effects on ROM in all species, however, the degree of stability achieved differed. Especially in axial rotation, the ROM of sheep, pig and calf was partially less than half the human ROM. Similarly, implantation of the Wave-S Cage caused the ROM to either increase in both species or to decrease in both of them, however, quantitatively, differences were observed. This was also the case for the sintering. In conclusion, animal species, especially the calf, may be used to get a first idea of how a new pedicle screw system or interbody cages behave in in vitro flexibility tests. However, the effects on ROM and intering tendency have to be expected to differ in magnitude between animal and human. Therefore, the last step in preclinical implant testing should always be an experiment with human specimens.
Description
Faculties
Medizinische Fakultät
Institutions
DFG Project uulm
EU Project uulm
Other projects uulm
Citation
Is version of
Has version
Supplement to
Supplemented by
Has erratum
Erratum to
Has Part
Part of
DOI external
DOI external
Institutions
Periodical
Degree Program
DFG Project THU
EU Project THU
Other projects THU
Series
Collections
Endorsement
Review
Supplemented By
Referenced By
Zeitraum:
Creative Commons license
Except where otherwised noted, this item's license is described as Standard (Fassung vom 03.05.2003)