Resorbierbare- versus Titanimplantate bei Frakturen im Kieferwinkelbereich - Vergleichsstudie zur Stabilität von Osteosynthesen im biomechanischen Modellversuch

Thumbnail
Download
vts_6425_8674.pdf (4.148Mb)
104 Seiten
 
Veröffentlichung
2008-06-24
DOI
10.18725/OPARU-1424
Dissertation


Authors
Hilscher, Christian
Faculties
Medizinische Fakultät
License
Standard (Fassung vom 03.05.2003)
https://oparu.uni-ulm.de/xmlui/license_v1
Abstract
Resorbable- versus titanium implants for the treatment of mandibular angle fractures - a comparison of the stability in a biomechanical in vitro examination. Background: The use of semi rigid titanium systems for the treatment of mandibular angle fractures becomes more and more clinical routine. Mostly low profile miniplates (2.0 mm, 1.5 mm) are used for the internal fixation. This investigation should show if resorbable miniplates may be able to provide the same stability as titanium plates. Material and methods: In the present study a biomechanical in vitro model (mandibular strain simulator) is used to examine the stability of different resorbable and titanium plates used for the fixation of a mandibular angle fracture in an artificial mandible (synbone). Three titanium systems (Synthes 2.0, 1.5 and 1.3) and four resorbable systems (Inion CPS 2.5 and 1.5, Lactosorb 2.0, MacroSorb 1.5) have been tested. Results: There have been only small differences between the resorbable and the titanium fixation systems. The Synthes 2.0 titanium plating system has shown the biggest Stability of all systems, followed by Inion 2.5, Lactosorb 2.0, MacroSorb 1.5, Inion 1.5 and Synthes 1.5 and 1.3. Conclusion: In terms of stability of the fixation, the plate-screw-compound and their specific mechanical characteristics, resorbable miniplates provide nearly the same stability as titanium miniplates. To reach an equal stability as a titanium miniplate, a slightly bigger resorbable plating system should be used.
Date created
2007
Subject Headings
Osteosynthese [GND]
Mandibular fractures. Therapy [MeSH]
Keywords
Kieferwinkel; resorbierbar; Stabilität; Titanosteosynthesesysteme; Unterkiefersimulator
Dewey Decimal Group
DDC 610 / Medicine & health

Metadata
Show full item record

Citation example

Hilscher, Christian (2008): Resorbierbare- versus Titanimplantate bei Frakturen im Kieferwinkelbereich - Vergleichsstudie zur Stabilität von Osteosynthesen im biomechanischen Modellversuch. Open Access Repositorium der Universität Ulm. Dissertation. http://dx.doi.org/10.18725/OPARU-1424

Other citation formats



About OPARU | Contact Us
Impressum | Privacy statement
 

 

Advanced Search

Browse

All of OPARUCommunities & CollectionsFacultiesInstitutionsPersonsResource typesUlm SerialsDewey Decimal ClassesFundingThis CollectionFacultiesInstitutionsPersonsResource typesUlm SerialsDewey Decimal ClassesFunding

My Account

LoginRegister

Statistics

View Usage Statistics

About OPARU | Contact Us
Impressum | Privacy statement