2D ultrashort echo‐time functional lung imaging
Loading...
Date
2020-07-11
Authors
Balasch, Anke
Metze, Patrick
Stumpf, Kilian
Beer, Meinrad
Büttner, Susanne M.
Rottbauer, Wolfgang
Speidel, Tobias
Rasche, Volker
Journal Title
Journal ISSN
Volume Title
Publication type
Document version
publishedVersion
Distributor
Universität Ulm
Published in
Journal of Magnetic Resonance Imaging, 2020
Abstract
Background
Imaging of the lung by MRI is challenging due to the intrinsic low proton density and rapid T2* relaxation. MRI methods providing lung parenchyma and function are in demand.
Purpose
To investigate the feasibility of two‐dimensional ultrashort echo‐time (2D UTE) imaging for lung function assessment.
Study Type
Prospective.
Population
Eleven healthy volunteers.
Field Strength/Sequence
3T, 2D tiny golden angle UTE (2D‐tyUTE).
Assessment
The applicability of breath‐hold (BH) and self‐gated (SG) 2D‐tyUTE for quantification of the lung parenchyma signal‐to‐noise ratio (SNR), proton fraction (fP), fractional ventilation (FV), and perfusion (f) was investigated. Dependencies on repetition time (BHS/I1/I2) and respiratory phase (expiration [EX], inspiration [IN]) were investigated and compared between smokers and nonsmokers.
Statistical Tests
Analysis of variance (ANOVA), Kendell's W.
Results
Significant differences of SNR (EX: 10.98 ± 3.19(BHS), 14.58 ± 3.89(BHI1), 17.59 ± 4.92(BHI2), 11.00 ± 5.42(SG); IN: 7.17 ± 2.07(BHS), 9.51 ± 2.37(BHI1), 10.49 ± 2.33(BHI2), 10.00 ± 4.14(SG)) (P < 0.05 for all cases) were observed between the different approaches. Where fP in expiration (0.41 ± 0.13) was independent of the BH imaging technique, it was slightly higher in SG (0.44 ± 0.06). FV was reproducible among the BH techniques (0.41 ± 0.10), but significantly lower in SG (0.21 ± 0.06) (P < 0.05). A moderate correlation (R2 = 0.47, P < 0.01) was observed between the breathing amplitude and FV. No significant differences between BH and SG were observed for the perfusion analysis (EX: 3.50 ± 1.29 mL/min/mL [BHS]; IN: 2.36 ± 1.05 mL/min/mL [BHS]). Significant differences in fP were found between smokers (0.48 ± 0.11 BH) and nonsmokers (0.37 ± 0.12 BH) in expiration.
Data Conclusion
This study demonstrates the feasibility of 2D‐tyUTE for successful quantification of relevant lung function parameters at 3T within clinically attractive acquisition times. The low spatial resolution into the slice selection direction may limit the final sensitivity and needs further clinical evaluation.
Level of Evidence
2
Technical Efficacy Stage
1 J. MAGN. RESON. IMAGING 2020;52:1637–1644.
Description
Faculties
Medizinische Fakultät
DFG Project uulm
EU Project uulm
Other projects uulm
Citation
Is version of
Has version
Supplement to
Has erratum
Erratum to
Has Part
Part of
DOI external
DOI external
10.1002/jmri.27269
Institutions
Periodical
Degree Program
DFG Project THU
EU Project THU
Other projects THU
Series
Collections
Endorsement
Review
Supplemented By
Referenced By
Zeitraum:
Creative Commons license
Except where otherwised noted, this item's license is described as CC BY-NC 4.0 International