Abstract
In this dissertation novel marker system were characterized and evaluated for their ability to discriminate between forensically relevant body fluids with a specific focus on simultaneous detection within mixtures. Two different methods were investigated in detail for this purpose: DNA methylation pattern analysis and immunochromatographic assays.
The potential use of DNA methylation markers for the identification of body fluids has been indicated by recent advances in whole genome epigenetic analyses and proposed markers for the detection of blood, vaginal secretions, semen, and saliva were evaluated in this work. Markers were identified and validated for the identification of menstrual fluid, semen, and saliva in single source stains as well as in mixtures of several body fluids. Subsequently, four markers were combined into a multiplex array for the simultaneous detection of these body fluids. Additionally, DNA methylation markers were identified for the discrimination of menstrual fluid and blood, which can be especially useful in alleged sexual assaults. With the results of this work it was shown that DNA methylation pattern analysis might be an advantageous alternative over existing methods for forensic body fluid identification.
Furthermore, the high potential of protein markers for menstrual fluid identification is presented in this work. With these assays the identification of menstrual fluid is based on the detection of D- dimers, the highly abundant product of fibrinolysis in menstrual fluid. An immunochromatographic strip test assay was evaluated and validated for the detection of menstrual fluid and therefore the discrimination of menstrual fluid and peripheral blood. Moreover, the analysis of mixtures of body fluids with immunochromatographic assays was realized by combining commercially available assays into a multiplex array. With this array, the simultaneous detection of five body fluids, i.e. semen, saliva, urine, menstrual fluid, and blood was achieved. The array showed to be highly sensitive and specific, easy in use, and the analysis of body fluid mixtures was straightforward. Through the inclusion of novel markers for menstrual fluid and the understanding that immunochromatographic assays have the potential to be multiplexed, these assays also remain a valuable tool in forensic science.
Description
Faculties
Medizinische Fakultät
DFG Project uulm
Other projects uulm
Citation
Is version of
Has version
Supplement to
Supplemented by
Has erratum
Erratum to
Has Part
H. Holtkötter, L. Dierig, M. Schürenkamp, U. Sibbing, H. Pfeiffer, M. Vennemann, Validation of an immunochromatographic D-dimer test to presumptively identify menstrual fluid in forensic exhibits, Int. J. Legal Med.
H. Holtkötter, V. Beyer, K. Schwender, A. Glaub, K.S. Johann, M. Schürenkamp, U. Sibbing, S. Banken, P. Wiegand, H. Pfeiffer, L. Dennany, M. Vennemann, EUROFORGEN-NoE Consortium, Independent validation of body fluid-specific CpG markers and construction of a robust multiplex assay, Forensic Sci. Int. Genet.
H. Holtkötter, C. Rodrigues Filho, K. Schwender, C. Stadler, M. Vennemann, A.C. Pacheco, M.G. Roca, Forensic differentiation between peripheral and menstrual blood in cases of alleged sexual assault - validating an immunochromatographic multiplex assay for simultaneous detection of human hemoglobin and D-dimer, Int. J. Leg. Med.
H. Holtkötter, K. Schwender, P. Wiegand, H. Pfeiffer, M. Vennemann, Improving body fluid identification in forensic trace evidence - construction of an immunochromatographic test array to rapidly detect up to five body fluids simultaneously, Int. J. Legal Med.
H. Holtkötter, P. Wiegand, K. Schwender, H. Pfeiffer, M. Vennemann, Marker evaluation for differentiation of blood and menstrual fluid by methylation-sensitive SNaPshot analysis, Int. J. Legal Med.
H. Holtkötter, V. Beyer, K. Schwender, A. Glaub, K.S. Johann, M. Schürenkamp, U. Sibbing, S. Banken, P. Wiegand, H. Pfeiffer, L. Dennany, M. Vennemann, EUROFORGEN-NoE Consortium, Independent validation of body fluid-specific CpG markers and construction of a robust multiplex assay, Forensic Sci. Int. Genet.
H. Holtkötter, C. Rodrigues Filho, K. Schwender, C. Stadler, M. Vennemann, A.C. Pacheco, M.G. Roca, Forensic differentiation between peripheral and menstrual blood in cases of alleged sexual assault - validating an immunochromatographic multiplex assay for simultaneous detection of human hemoglobin and D-dimer, Int. J. Leg. Med.
H. Holtkötter, K. Schwender, P. Wiegand, H. Pfeiffer, M. Vennemann, Improving body fluid identification in forensic trace evidence - construction of an immunochromatographic test array to rapidly detect up to five body fluids simultaneously, Int. J. Legal Med.
H. Holtkötter, P. Wiegand, K. Schwender, H. Pfeiffer, M. Vennemann, Marker evaluation for differentiation of blood and menstrual fluid by methylation-sensitive SNaPshot analysis, Int. J. Legal Med.
Part of
DOI external
DOI external
10.1016/j.fsigen.2017.05.002
10.1007/s00414-014-1097-7
10.1007/s00414-017-1719-y
10.1007/s00414-017-1724-1
10.1007/s00414-018-1770-3
10.1007/s00414-014-1097-7
10.1007/s00414-017-1719-y
10.1007/s00414-017-1724-1
10.1007/s00414-018-1770-3
Institutions
Periodical
Degree Program
DFG Project THU
EU Project THU
Other projects THU
Series
Collections
Endorsement
Review
Supplemented By
Referenced By
Zeitraum:
Creative Commons license
Except where otherwised noted, this item's license is described as Standard