<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Accuracy of pulse oximetry during neonatal resuscitation

dc.contributor.authorHassan, Mohammad Ahmad
dc.contributor.refereeMuth, Claus-Martin
dc.contributor.refereeMeißner, Peter
dc.contributor.refereeHummler, Helmut
dc.date.accessioned2017-03-24T10:28:37Z
dc.date.available2017-03-24T10:28:37Z
dc.date.created2014de
dc.date.issued2017-03-24de
dc.description.abstractBackground: Pulse oximetry is widely used in intensive care and emergency conditions to monitor arterial oxygenation and to guide oxygen therapy. Objective: To study the reliability of pulse oximetry in comparison with CO-oximetry in newborn piglets during cardiopulmonary resuscitation (CPR). Methodology: In a prospective cohort study in 30 healthy newborn piglets, cardiac arrest was induced, and thereafter each piglet received CPR for 20 min. Arterial oxygen saturation was monitored continuously by pulse oximetry (SpO2). Arterial blood was analyzed for functional oxygenation (SaO2) every 2 min. SpO 2 was compared with coinciding SaO2 values and bias considered whenever the difference (SpO 2 – SaO 2 ) was beyond ±5%. Results: Bias values were decreased at the baseline measurements (mean: 2.5 ± 4.6%) with higher precision and accuracy compared with values across the experiment. Two minutes after cardiac arrest, there was a marked decrease in precision and accuracy as well as an increase in bias up to 13 ± 34%, reaching a maximum of 45.6 ± 28.3% after 10 min over a mean SaO 2 range of 29–58%. Conclusion: Pulse oximetry showed increased bias and decreased accuracy and precision during CPR in a model of neonatal cardiac arrest. We recommend further studies to clarify the exact mechanisms of these false readings to improve reliability of pulse oximetry during the marked desaturation and hypoperfusion found during CPR.de
dc.identifier.doihttp://dx.doi.org/10.18725/OPARU-4284
dc.identifier.ppn883628201
dc.identifier.urlhttps://oparu.uni-ulm.de/xmlui/123456789/4323
dc.identifier.urnhttp://nbn-resolving.de/urn:nbn:de:bsz:289-oparu-4323-7
dc.language.isoende
dc.publisherUniversität Ulm
dc.rightsStandardde
dc.rights.urihttps://oparu.uni-ulm.de/xmlui/license_v3
dc.subjectKardiopulmonale Reanimationde
dc.subject.ddcDDC 610 / Medicine & healthde
dc.subject.gndWiederbelebungde
dc.subject.gndOxymetriede
dc.subject.meshCardiopulmonary resucitationde
dc.subject.meshOximetryde
dc.subject.meshIntensive care, neonatalde
dc.subject.meshModels, animalde
dc.titleAccuracy of pulse oximetry during neonatal resuscitationde
dc.typeDissertationde
dcterms.dateAccepted2016-10-21
uulm.affiliationGeneralMedizinische Fakultätde
uulm.affiliationSpecificUKU. Klinik für Anästhesiologiede
uulm.affiliationSpecificUKU. Klinik für Kinder- und Jugendmedizinde
uulm.bibliographieuulm
uulm.categoryPublikationen
uulm.shelfmarkW: W-H 15.049
uulm.thesisGrantorMedizinische Fakultätde
uulm.typeDCMITextde
uulm.updateStatusURNurn_new
uulm.veroeffentlichungErstveröffentlichungde

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Thesis_Hassan.pdf
Size:
1.45 MB
Format:
Adobe Portable Document Format
Description:

Collections