<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Optimierung der DNA-Analyse für degradierte biologische Spuren

dc.contributor.authorMüller, Kathrin
dc.date.accessioned2016-03-15T06:24:28Z
dc.date.available2016-03-15T06:24:28Z
dc.date.created2009
dc.description.abstractNowadays more and more difficult biological stains are taken up at crime scenes, i.e. stains, polluted with environmental contaminants or stains with highly degraded and LCN DNA, thereunder telogen hairs and hair shafts. Inhibitors, which are present in many stains, can disrupt the PCR reaction, unless they cannot be separated from the DNA during the extraction. To increase the chances of a correct typing of degraded biological stains, the small amount of DNA must be successfully isolated and the inhibitors have to be removed or neutralized. A modified GEN-IAL extraction in combination with a silica-purifaction could be successfully used for such stains. For the PCR optimization several polymerases, buffers, PCR additives were tested. A PCR optimization could be successfully exercised for bloodstains and hairs. The inhibitory effect of the hair pigment Melanin could be compensated by increasing the MgCl2- and polymerase-concentration. DNA from blood could be successfully amplificated by using a polymerase which is less sensitive to the haemoglobin. Weak stains with highly degraded DNA may be hard to analyse due to the long amplicon lengths produced by the commercial STR kits. To increase the success rate especially in typing degraded biological stains, sensitive STR multiplex kits with shortened amplicon lengths are useful. Therefore two sensitive STR (Short Tandem Repeat) kits were developed. Compared to commercial kits the amplicon lengths were significantly reduced. The autosomal STR multiplex (Q8) comprises the German DNA database systems. The gonosomal STR multiplex Y13 comprises 13 Y-specific STR-markers. Male DNA in a mixed stain with excess of female DNA could be analysed using the Y13, while typing with autosomal markers would be no more practicable. Compared to commercial STR kits these two concepts (Q8 and Y13) resulted in considerably higher success rates for degraded biological stains, which are often found in the forensic casework testing.
dc.identifier.doihttp://dx.doi.org/10.18725/OPARU-2005
dc.identifier.ppn1648617387
dc.identifier.urlhttps://oparu.uni-ulm.de/xmlui/123456789/2032
dc.identifier.urnhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-71670
dc.language.isode
dc.publisherUniversität Ulm
dc.rightsStandard (Fassung vom 01.10.2008)
dc.rights.urihttps://oparu.uni-ulm.de/xmlui/license_v2
dc.subjectDNA degradation
dc.subjectDNA typing
dc.subjectGerman DNA database systems
dc.subjectLow copy number
dc.subjectPCR opimization
dc.subjectShort amplicon multiplex
dc.subject.ddcDDC 570 / Life sciences
dc.subject.gndGenetischer Fingerabdruck
dc.subject.lcshForensic sciences
dc.subject.meshDNA. Isolation and purification
dc.titleOptimierung der DNA-Analyse für degradierte biologische Spuren
dc.typeDissertation
uulm.affiliationGeneralMedizinische Fakultät
uulm.bibliographieuulm
uulm.categoryPublikationen
uulm.freischaltungVTS2010-01-04T15:26:54Z
uulm.peerReviewnein
uulm.shelfmarkZ: J-H 13.525; W: W-H 11.950
uulm.typeDCMIText
uulm.updateStatusURNurl_update_general
uulm.vtsID7167

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
vts_7167_10080.pdf
Size:
44.86 MB
Format:
Adobe Portable Document Format
Description:
194 Seiten

Collections