Computergestützte Volumetrie von CT-Daten bei Patienten mit konservativer Therapie einer Aortendissektion Typ B nach Stanford
| dc.contributor.author | Giannakidou, Ekaterini | |
| dc.date.accessioned | 2016-03-14T13:40:55Z | |
| dc.date.available | 2016-03-14T13:40:55Z | |
| dc.date.created | 2006 | |
| dc.description.abstract | Computer assisted volumetry of CT data in patients with medically treated Stanford type B dissection Purpose: The purpose of this study was to document an increase in volume of the false and true lumen of the aorta in patients with medically treated Stanford type B dissection. Afterwards there was a comparison with the method of diameter measurement. Materials and Methods: Fourteen patients with medically treated aortic dissection type B underwent controls by computed tomography in variable intervals to look for changes in aortal structure (enlargement of the aortic diameter / thrombosed false lumen). These CT-series were processed with a special program named OSIRIS which calculates the volume of the true and the false Lumen of the aortic dissection that have been marked manually in a CT-image. Results: In case of eleven patients the volume of true and false lumen increased. Conclusion: Volumetry is an exact method to demonstrate an increasement in the lumen of aortic dissection. Three-dimensional images give an idea of the aortal expansion. | |
| dc.identifier.doi | http://dx.doi.org/10.18725/OPARU-740 | |
| dc.identifier.ppn | 60855880X | |
| dc.identifier.url | https://oparu.uni-ulm.de/xmlui/123456789/767 | |
| dc.identifier.urn | http://nbn-resolving.de/urn:nbn:de:bsz:289-vts-57590 | |
| dc.language.iso | de | |
| dc.publisher | Universität Ulm | |
| dc.rights | Standard (Fassung vom 03.05.2003) | |
| dc.rights.uri | https://oparu.uni-ulm.de/xmlui/license_v1 | |
| dc.subject | Aortendissektion Typ B | |
| dc.subject.ddc | DDC 610 / Medicine & health | |
| dc.subject.gnd | Computertomographie | |
| dc.subject.gnd | Maßanalyse | |
| dc.subject.mesh | Aortic diseases. Surgery | |
| dc.title | Computergestützte Volumetrie von CT-Daten bei Patienten mit konservativer Therapie einer Aortendissektion Typ B nach Stanford | |
| dc.type | Dissertation | |
| uulm.affiliationGeneral | Medizinische Fakultät | |
| uulm.bibliographie | uulm | |
| uulm.category | Publikationen | |
| uulm.freischaltungVTS | 2006-12-13T08:38:06Z | |
| uulm.peerReview | nein | |
| uulm.shelfmark | Z: J-H 11.321 ; W: W-H 9.432 | |
| uulm.typeDCMI | Text | |
| uulm.updateStatusURN | url_update_general | |
| uulm.vtsID | 5759 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- vts_5759_7658.pdf
- Size:
- 2.6 MB
- Format:
- Adobe Portable Document Format
- Description:
- 80 Seiten