High immunoglobulin M surface expression on chronic lymphocytic leukemia cells as a potential new prognostic factor
Loading...
Date
2026-06-12
Authors
Ruhstorfer, Rebecca
Journal Title
Journal ISSN
Volume Title
Publication type
Document version
Distributor
Universität Ulm
Published in
Abstract
Chronic lymphocytic leukemia (CLL) is characterized by a highly heterogeneous clinical course. Recent studies have demonstrated that the ratio of surface immunoglobulins IgM and IgD plays a decisive role: a low IgD to IgM quotient (DvM-Score < 1.15) correlates with a shorter time to first treatment (TTFT). The aim of this study was to develop and validate a time-efficient, practical flow cytometry (FACS) method for quantifying the DvM-Score. By utilizing reference beads, the prognostically relevant threshold was to be visualized directly in an X-Y plot, enabling rapid clinical assessment without the need for complex manual calculations. Monodisperse polystyrene microspheres (beads) were functionalized with defined quantities of human IgD and monomeric IgM. To ensure stability, IgM was monomerized prior to coupling and verified via SDS-PAGE and ELISA. These beads served as internal calibrators with a target ratio of 1.15. In the FACS analysis, patient samples (n > 100) were measured simultaneously with the beads. By plotting the fluorescence intensities of IgM and IgD in an X-Y dot plot, a reference line was generated between uncoated and coupled beads, acting as a decision boundary for risk stratification. Stable reference beads with a precise DvM-Score of 1.17 were successfully produced. Graphical analysis showed high concordance with the mathematical determination via Mean Fluorescence Intensity (MFI): samples with a low DvM-Score were reproducibly positioned below the boundary line defined by the beads, while samples with a favorable profile appeared above it. Technical hurdles, such as interference from bovine serum albumin (BSA) in the stabilization buffer, were identified and resolved through process optimization. The use of antigen-specifically coupled beads enables a rapid, visual, and standardized determination of the BCR ratio in CLL patients. This method reduces the required workflow steps in everyday clinical practice and offers the potential to be expanded as a modular diagnostic tool for other surface-bound biomarkers.
Description
Faculties
Medizinische Fakultät
DFG Project uulm
EU Project uulm
Other projects uulm
Citation
Is version of
Has version
Supplement to
Supplemented by
Has erratum
Erratum to
Has Part
Part of
DOI external
DOI external
Institutions
Periodical
Degree Program
DFG Project THU
EU Project THU
Other projects THU
Series
Collections
Endorsement
Review
Supplemented By
Referenced By
Zeitraum:
Creative Commons license
Except where otherwised noted, this item's license is described as CC BY 4.0 International

