<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

High immunoglobulin M surface expression on chronic lymphocytic leukemia cells as a potential new prognostic factor

Loading...
Thumbnail Image

Date

2026-06-12

Authors

Ruhstorfer, Rebecca

Journal Title

Journal ISSN

Volume Title

Publication type

Document version

Distributor

Universität Ulm

Published in

Abstract

Chronic lymphocytic leukemia (CLL) is characterized by a highly heterogeneous clinical course. Recent studies have demonstrated that the ratio of surface immunoglobulins IgM and IgD plays a decisive role: a low IgD to IgM quotient (DvM-Score < 1.15) correlates with a shorter time to first treatment (TTFT). The aim of this study was to develop and validate a time-efficient, practical flow cytometry (FACS) method for quantifying the DvM-Score. By utilizing reference beads, the prognostically relevant threshold was to be visualized directly in an X-Y plot, enabling rapid clinical assessment without the need for complex manual calculations. Monodisperse polystyrene microspheres (beads) were functionalized with defined quantities of human IgD and monomeric IgM. To ensure stability, IgM was monomerized prior to coupling and verified via SDS-PAGE and ELISA. These beads served as internal calibrators with a target ratio of 1.15. In the FACS analysis, patient samples (n > 100) were measured simultaneously with the beads. By plotting the fluorescence intensities of IgM and IgD in an X-Y dot plot, a reference line was generated between uncoated and coupled beads, acting as a decision boundary for risk stratification. Stable reference beads with a precise DvM-Score of 1.17 were successfully produced. Graphical analysis showed high concordance with the mathematical determination via Mean Fluorescence Intensity (MFI): samples with a low DvM-Score were reproducibly positioned below the boundary line defined by the beads, while samples with a favorable profile appeared above it. Technical hurdles, such as interference from bovine serum albumin (BSA) in the stabilization buffer, were identified and resolved through process optimization. The use of antigen-specifically coupled beads enables a rapid, visual, and standardized determination of the BCR ratio in CLL patients. This method reduces the required workflow steps in everyday clinical practice and offers the potential to be expanded as a modular diagnostic tool for other surface-bound biomarkers.

Description

Faculties

Medizinische Fakultät

DFG Project uulm

EU Project uulm

Other projects uulm

Citation

Is version of

Has version

Supplement to

Supplemented by

Has erratum

Erratum to

Has Part

Part of

DOI external

DOI external

Institutions

Periodical

Degree Program

DFG Project THU

EU Project THU

Other projects THU

Series

Collections

Endorsement

Review

Supplemented By

Referenced By

Zeitraum:

Creative Commons license

Except where otherwised noted, this item's license is described as CC BY 4.0 International