Cartilage tribology in the osteoarthritic human knee : insights from the joint to the tissue level
| dc.contributor.author | de Roy, Luisa | |
| dc.contributor.referee | Seitz, Andreas Martin | |
| dc.contributor.referee | Seehaus, Frank | |
| dc.date.accessioned | 2026-08-21T10:13:58Z | |
| dc.date.available | 2026-08-21T10:13:58Z | |
| dc.date.created | 2025 | |
| dc.date.issued | 2026-08-21 | |
| dc.description.abstract | Emerging evidence suggests that altered friction plays a role in osteoarthritis (OA) pathogenesis by initiating a vicious cycle of inflammation and matrix degradation. However, the friction properties of osteoarthritic human articular cartilage (AC) remain poorly understood, because tribological aspects are underrepresented in OA research. Therefore, this cumulative thesis aimed to provide multi-level insights into AC tribology in the osteoarthritic human knee. Given the proposed link between altered friction and OA, together with the load-dependent nature of AC friction, it is important to identify loading conditions which contribute to the highest friction. To address this, an ex-vivo study was conducted on human AC samples obtained from patients undergoing total knee arthroplasty. Each sample was subjected to four distinct loading conditions representative of daily activities during friction testing. They were tested against glass as the counter-surface while being lubricated with patient-specific synovial fluid (SF). The findings revealed that osteoarthritic AC samples exhibited a diminished ability to maintain low friction particularly under stance-phase loading. This suggested that prolonged high loading could be a risk factor for triggering OA progression by increased friction. Building upon these findings under quasi-static conditions, the frictional properties of AC samples at different stages of OA severity were examined under dynamic gait-like loading conditions in more detail. The samples were tested against glass and cartilage as counter surfaces to assess their tribological functionality during both, boundary and fluid-mediated lubrication mechanisms. Synthetic synovial fluid was used as a lubricant in these experiments. The results demonstrated that AC friction during gait is highly sensitive to alterations in the boundary lubrication regime, whereas the interstitial fluid pressurization lubrication appeared to be effective in mitigating increased friction. Furthermore, the tribological effect of intra-articular hyaluronic acid (HA) injections, a commonly used non-surgical treatment option for OA, was investigated at both the joint and tissue levels. Whole-joint friction was assessed using a passive pendulum testing routine, followed by additional tissue-level experiments in a pin-on-plate tribometer. In each test, the friction-reducing potential of supplemented HA was evaluated in comparison to the native condition. The results consistently indicated that adding HA to the tribosystem did not significantly alter the frictional behavior, neither at the joint nor the tissue level. These findings suggested that therapeutic benefits seen in patients are not primarily driven by initial tribomechanical effects. Both, the tribological and biomechanical properties of the AC are closely linked to its biphasic structure. Biomechanical changes in AC such as reduced stiffness or increased permeability frequently occur during the early stages of OA. While image-based assessments can provide insights into the in-vivo biomechanical properties, there is currently no method available to evaluate the AC’s tribological functionality. Should biomechanical changes correlate with alterations in AC friction, this might allow for earlier OA diagnosis and intervention. The viscoelastic properties were derived from spatial indentation testing in which the AC composite remained intact and from a stress-relaxation test on subsequently isolated samples. Friction was assessed in a cartilage-against-glass configuration with patient-specific SF as lubricant under gait-like loading. The findings indicated that the microscopic structure of the AC might be an objective measure to derive its tribological functionality. However, correlations between the viscoelastic and frictional behaviors of the AC were only observed in the properties of the isolated samples. It currently remains unclear whether there is an interplay between the dual functionality of the tissue when the AC surface is left intact during both, biomechanical and friction testing. To provide a method that is suitable to fill this knowledge gap in the future, the TriBot was developed, a robotic-based tribometer capable of measuring friction on curved joint surfaces. A six-axis industrial robot allows to move a pin along trajectories while simultaneously accounting for an orthogonal positioning of the pin to the sample surface. The suitability of the robotic tribometer to measure friction on complex shapes was demonstrated. For system validation, the friction coefficients of polyoxymethylene pins on three different polyamide (PA) shapes were determined. The robotic tribometer was considered as successfully validated because the friction coefficients showed no significant differences between the PA samples of different shape complexity. In the second part of the study, friction was assessed on porcine tibial plateau surfaces. The AC was tested in the intact condition and after creating an anteromedial defect using sandpaper. The results indicated that the robotic tribometer is suitable to investigate entire AC surfaces while being sufficiently sensitive to detect local differences in AC friction attributable to structural changes. This is of particular interest in the context of OA, because the identification of areas with tribological imbalances may enable more targeted therapeutic interventions to successfully decelerate OA progression. The robotic tribometer has the potential to complement the current tribological knowledge by building upon the multi-level insights presented in this cumulative dissertation. Overall, the findings presented in this thesis contribute to a deeper understanding of the pathophysiology of osteoarthritic AC, particularly from a tribological perspective, and may provide a basis for improving the diagnostic tools and treatment of patients who suffer from OA. | |
| dc.identifier.doi | https://doi.org/10.18725/OPARU-60925 | |
| dc.identifier.url | https://oparu.uni-ulm.de/handle/123456789/61000 | |
| dc.identifier.urn | http://nbn-resolving.de/urn:nbn:de:bsz:289-oparu-61000-5 | |
| dc.language.iso | en | |
| dc.publisher | Universität Ulm | |
| dc.relation.haspart | de Roy L, Metzger JW, Faschingbauer M, Ignatius A, Seitz AM. Friction of osteoarthritic cartilage with patient-specific synovial fluid: Effect of different loading conditions. Osteoarthritis and Cartilage Open. 2025, 7(1). https://doi.org/10.1016/j.ocarto.2025.100568 | |
| dc.relation.haspart | de Roy L, Schlickenrieder K, Rüger M, Faschingbauer M, Ignatius A, Seitz AM. Impact of degeneration and material pairing on cartilage friction: cartilage versus glass. Journal of Orthopaedic Research. 2023, 42(4): p. 745-752. https://doi.org/10.1002/jor.25738 | |
| dc.relation.haspart | de Roy L, Eichhorn K, Faschingbauer M, Schlickenrieder K, Ignatius A, Seitz AM. Impact of hyaluronic acid injection on the knee joint friction. Knee Surgery, Sports Traumatology, Arthroscopy. 2023, 31(12): p. 5554-64. https://doi.org/10.1007/s00167-023-07602-w | |
| dc.relation.haspart | de Roy L, Teixeira GQ, Schwer J, Sukopp M, Faschingbauer M, Ignatius A, Seitz AM. Structure–function of cartilage in osteoarthritis: an ex-vivo correlation analysis between its structural, viscoelastic and frictional properties. Acta Biomaterialia. 2024, 190: p. 293-302. https://doi.org/10.1016/j.actbio.2024.10.027 | |
| dc.relation.haspart | de Roy L, Roderigo M, Schwer J, Schlickenrieder K, Ignatius A, Seitz AM. Proof-ofconcept study of the TriBot: a robot-based test setup for biotribological analyses of curved articular surfaces. Frontiers in Bioengineering and Biotechnology. 2025, 13. https://doi.org/10.3389/fbioe.2025.1546060 | |
| dc.rights | CC BY 4.0 International | |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
| dc.subject.ddc | DDC 610 / Medicine & health | |
| dc.subject.gnd | Reibung | |
| dc.subject.gnd | Knorpel | |
| dc.subject.mesh | Friction; Physiology | |
| dc.subject.mesh | Cartilage diseases; Therapy | |
| dc.title | Cartilage tribology in the osteoarthritic human knee : insights from the joint to the tissue level | |
| dc.type | Dissertation | |
| dcterms.dateAccepted | 2026-05-07 | |
| uulm.affiliationSpecific | UKU. Institut für Unfallchirurgische Forschung und Biomechanik | |
| uulm.bibliographie | uulm | De |
| uulm.category | Publikationen | |
| uulm.thesisGrantor | Medizinische Fakultät | |
| uulm.typeDCMI | Text | |
| uulm.updateStatusURN | url_update_general |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Dissertation_deRoy.pdf
- Size:
- 55.69 MB
- Format:
- Adobe Portable Document Format
