<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Untersuchungen zum Einsatz des Comet Assays im Biomonitoring

dc.contributor.authorWitton-Davies, Thomas Lyn
dc.date.accessioned2016-03-14T13:41:13Z
dc.date.available2016-03-14T13:41:13Z
dc.date.created2006
dc.description.abstractThe comet assay (single-cell gel electrophoresis, SCG) is widely accepted as an in vitro and in vivo genotoxicity test. Because of its demonstrated ability to detect various kinds of DNA damage and its ease of application, the technique is being increasingly used in human biomonitoring. However, the assessment of small genotoxic effects as typically obtained in biomonitoring may be limited by the different sources of assay variability and the lack of an optimal protocol with high sensitivity. To better characterize the suitability of the comet assay for biomonitoring, we are performing a comprehensive investigation on blood samples from smokers and non-smokers. Because tobacco smoke is a well-documented source of a variety of potentially mutagenic and carcinogenic compounds, smokers should be a suitable study group with relevant mutagen exposure. Here, we report our results for the first sample of 20 healthy male smokers and 20 healthy male non-smokers. Baseline and benzo[a]pyrene diolepoxide (BPDE)-induced effects were analysed by two investigators using two image analysis systems. The study was repeated within 4 months. Furthermore, the influence of a repair inhibitor (aphidicolin, APC) on baseline and BPDE-induced DNA damage was comparatively analysed. In all experiments, a reference standard (untreated V79 cells) was included to correct for assay variability. None of these approaches revealed significant differences between smokers and non-smokers. Although more data is needed for a final conclusion, this study indicates some limitations of the comet assay with regard to the detection of DNA damage induced by environmental mutagens in peripheral blood cells.
dc.identifier.doihttp://dx.doi.org/10.18725/OPARU-793
dc.identifier.ppn1651578001
dc.identifier.urlhttps://oparu.uni-ulm.de/xmlui/123456789/820
dc.identifier.urnhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-58682
dc.language.isode
dc.publisherUniversität Ulm
dc.rightsStandard (Fassung vom 03.05.2003)
dc.rights.urihttps://oparu.uni-ulm.de/xmlui/license_v1
dc.subjectAphidicolin
dc.subjectBenzo[a]pyren
dc.subjectbpde
dc.subjectCytochrom P-450 1A1
dc.subjectGlutathion-S-Transferase
dc.subject.ddcDDC 610 / Medicine & health
dc.subject.gndBiomonitoring
dc.subject.gndComet Assay
dc.subject.gndRauchen
dc.titleUntersuchungen zum Einsatz des Comet Assays im Biomonitoring
dc.typeDissertation
uulm.affiliationGeneralMedizinische Fakultät
uulm.bibliographieuulm
uulm.categoryPublikationen
uulm.freischaltungVTS2007-03-09T08:37:51Z
uulm.peerReviewnein
uulm.shelfmarkZ: J-H 11.406 ; W: W-H 9.514
uulm.typeDCMIText
uulm.updateStatusURNurl_update_general
uulm.vtsID5868

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
vts_5868_7839.pdf
Size:
1.18 MB
Format:
Adobe Portable Document Format
Description:
107 Seiten

Collections