<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Die mesenteriale Ischämie - diagnostische CT-Parameter im Vergleich

dc.contributor.authorStanescu-Siegmund, Nora
dc.date.accessioned2016-03-15T09:08:21Z
dc.date.available2016-03-15T09:08:21Z
dc.date.created2013
dc.description.abstractPurpose: The purpose of study was to compare the diagnostic value of a thick slap MIP projection in patients with mesenteric ischemia. Materials and methods: 36 individuals suspect of having mesenteric ischemia were included in the study. Standard biphasic (arterial and venous phase) computed tomography was performed in all patients. Two readers read the datasets twice in a randomized order. Reader 1 was a medical student, reader 2 an experienced radiologist. In the first read, the readers were instructed to read the datasets with the thick slap MIP projection, in the second read without MIP projection. Results: 26 out of the 36 patients turned out to have mesenteric ischemia confirmed by surgery and histopathology. Of the 26 patients having mesenteric ischemia, two turned out to have a non-occlusive disease. Sensitivity in detecting mesenteric ischemia was 76 % using the MIP projection and also without MIP projection and for reader 1. Specificity was 100 % for both reading methods. For reader 2 sensitivity without MIP projection was 76 % but 92 % without MIP projection. However, reader 2 increased specificity form 83 % up to 90 % using the MIP projection. Conclusion: A thick slap MIP projection does not increase readers sensitivity in detecting mesenteric ischemia. However, the experienced reader was able to increase specificity.
dc.identifier.doihttp://dx.doi.org/10.18725/OPARU-2988
dc.identifier.ppn774586303
dc.identifier.urlhttps://oparu.uni-ulm.de/xmlui/123456789/3015
dc.identifier.urnhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-87595
dc.language.isode
dc.publisherUniversität Ulm
dc.rightsStandard
dc.rights.urihttps://oparu.uni-ulm.de/xmlui/license_v3
dc.subjectDiagnostische Parameter
dc.subjectMesenterialischämie
dc.subjectMIP
dc.subject.ddcDDC 610 / Medicine & health
dc.subject.gndComputertomographie
dc.subject.meshIschemia
dc.subject.meshModels, statistical
dc.subject.meshTomography, X-ray computed
dc.titleDie mesenteriale Ischämie - diagnostische CT-Parameter im Vergleich
dc.typeDissertation
uulm.affiliationGeneralMedizinische Fakultät
uulm.bibliographieuulm
uulm.categoryPublikationen
uulm.freischaltungVTS2013-12-09T11:16:02Z
uulm.peerReviewnein
uulm.shelfmarkW: W-H 13.455
uulm.typeDCMIText
uulm.updateStatusURNurl_update_general
uulm.vtsID8759

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
vts_8759_13051.pdf
Size:
23.55 MB
Format:
Adobe Portable Document Format
Description:
51 S.

Collections