Applicability of three-dimensional ultra-short echo time magnetic resonance imaging for in vivo assessment of caries lesions and early demineralization

dc.contributor.authorHofmann, Christian
dc.date.accessioned2016-03-15T10:41:15Z
dc.date.available2016-03-15T10:41:15Z
dc.date.created2013
dc.description.abstractThe objective of this thesis was to investigate the potential of a new magnetic resonance imaging (MRI) technique at a high-field (3Tesla) whole-body clinical system for the assessment of caries lesions and early demineralization. In an initial in-vitro study it could be shown that with adjusted imaging parameters of the ultra-short echo time (UTE) sequence a clear delineation between the different hard dental tissues was feasible. In the following clinical study the aim was to investigate the transfer to patients. On the basis of two different MRI sequences for dental applications, one conventional multi-slice turbo spin-echo (MS-TSE) and one 3D ultra-short echo time (3D-UTE) sequence, the applicability for the detection of caries lesions was evaluated. The results were compared to the findings in existing conventional intra-oral X-ray images and four of the examined patients volunteered for additional in-situ documentation. In all cases, the dimensions of the caries lesions identified by 3D-UTE MRI were significantly larger than the respective dimensions in the X-ray images. Furthermore, the lesion extensions from the in-situ documentations confirm the lesion size in the 3D-UTE images and the respective underestimation in the X-ray images. In direct comparison of the two investigated MRI techniques, there was no advantage for the MS-TSE technique at any time, yet the 3D-UTE technique showed a much higher level of sensitivity than the MS-TSE technique. In summary, this clinical study enabled to obtain a sensitivity of 97.5 % for 3D-UTE, 85 % for X-ray and 17 % for MS-TSE.
dc.identifier.doihttp://dx.doi.org/10.18725/OPARU-3369
dc.identifier.ppn787877441
dc.identifier.urlhttps://oparu.uni-ulm.de/xmlui/123456789/3396
dc.identifier.urnhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-90074
dc.language.isoen
dc.publisherUniversität Ulm
dc.rightsStandard
dc.rights.urihttps://oparu.uni-ulm.de/xmlui/license_v3
dc.subjectUltra-short echo time sequence
dc.subjectUTE
dc.subject.ddcDDC 610 / Medicine & health
dc.subject.gndKaries
dc.subject.gndKernspintomographie
dc.subject.meshDental caries
dc.subject.meshMagnetic resonance imaging, dental
dc.subject.meshTooth demineralization
dc.titleApplicability of three-dimensional ultra-short echo time magnetic resonance imaging for in vivo assessment of caries lesions and early demineralization
dc.typeDissertation
uulm.affiliationGeneralMedizinische Fakultät
uulm.bibliographieuulm
uulm.categoryPublikationen
uulm.freischaltungVTS2014-06-05T14:01:15Z
uulm.peerReviewnein
uulm.shelfmarkW: W-H 13.647
uulm.typeDCMIText
uulm.updateStatusURNurl_update_general
uulm.vtsID9007

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
vts_9007_13534.pdf
Size:
1.92 MB
Format:
Adobe Portable Document Format
Description:
58 S.

Collections