Digitale Volumentomographie: Artefakte bei der Verwendung von Wurzelstiftsystemen in der Endodontie

dc.contributor.authorWalter, Alexander
dc.date.accessioned2016-03-15T10:42:13Z
dc.date.available2016-03-15T10:42:13Z
dc.date.created2014
dc.description.abstractThe aim of this study was to examine artifacts generated by various root canal systems in cone-beam computed tomography (cbct). Effects of material, geometrical shape, cbct settings/ artifact reduction program and the cbct’s themselves on the artifact morphology were analyzed and evaluated. KaVo Pan eXam Plus and the KaVo 3D eXam has been tested. The post materials zirconium dioxide, titanium, glass fiber reinforced composite and gutta-percha with a composite core were tested. For this purpose, cbct scans of the test groups and a control group in a dental arch model with different settings were recorded. The reconstructed volumes were evaluated through a specially developed examination sheet and the results were compared. The differences in the geometrical shape of the posts had no effect on the artifact morphology. The ceramic posts caused the strongest artifacts, they even had an influence on outlying areas. Artifacts could be assigned as streak-, extinction-, aliasing, ring- and other artifacts. The different artifacts often occured together. The artifact reduction algorithm didn’t reduce the artifacts significantly and even caused partially blurred pictures. The difference between the various tested volumes is very complex and can not establish a scheme that makes a statement about an improvement / deterioration of the artifact formation at a certain volume. The Pan eXam Plus caused most artifacts, but the scans were also more detailed. The results of this study show how much artifacts in cbct’s affect the evaluation and quality assessment in endodontics and lead to a loss of information and diagnostic misinterpretation. These results indicate the need for further studies and developments from the manufacturers of cbct’s to improve the image quality and to keep radiation exposure on patients as low as possible.
dc.identifier.doihttp://dx.doi.org/10.18725/OPARU-3606
dc.identifier.ppn826705987
dc.identifier.urlhttps://oparu.uni-ulm.de/xmlui/123456789/3633
dc.identifier.urnhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-95168
dc.language.isode
dc.publisherUniversität Ulm
dc.rightsStandard (ohne Print-On-Demand)
dc.rights.urihttps://oparu.uni-ulm.de/xmlui/license_opod_v1
dc.subjectCBCT
dc.subjectRoot canal post
dc.subject.ddcDDC 610 / Medicine & health
dc.subject.gndArtefakt <Bildgebende Diagnostik>
dc.subject.gndEndodontie
dc.subject.gndWurzelkanalbehandlung
dc.subject.meshArtifacts
dc.subject.meshCone-beam computed tomography
dc.subject.meshEndodontics
dc.titleDigitale Volumentomographie: Artefakte bei der Verwendung von Wurzelstiftsystemen in der Endodontie
dc.typeDissertation
uulm.affiliationGeneralMedizinische Fakultät
uulm.bibliographieuulm
uulm.categoryPublikationen
uulm.freischaltungVTS2015-05-12T14:25:59Z
uulm.peerReviewnein
uulm.shelfmarkW: W-H 14.182
uulm.typeDCMIText
uulm.updateStatusURNurl_update_general
uulm.vtsID9516