<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Migrationsanalyse des Fitmore-Kurzschaftes durch die Einzel-Bild-Röntgen-Analyse - Femoral-Component-Analysis-Methode

dc.contributor.authorFuchs, Michael
dc.date.accessioned2016-03-15T10:41:41Z
dc.date.available2016-03-15T10:41:41Z
dc.date.created2013
dc.description.abstractINTRODUCTION: Short-stem prostheses enable bone stock preserving total hip arthroplasty. However, little is known about the durability of this group of implants. The most common cause for implant failure is aseptic loosening. Early implant migration is supposed to be the best indicator for mechanical failure of femoral stems. The purpose of this study was to evaluate the migration pattern of a short stem implant and the influence of body mass index (BMI), diagnosis, gender and femoral offset on implant migration. MATERIALS AND METHODS: After a minimum follow-up of 2 years, 72 hips were included in this EBRA-FCA-study. The mean age at surgery of the 34 female and 32 male patients was 54 years (range 22 - 75 years). The mean BMI was 29 kg/m2 (range 21 - 51 kg/m2). RESULTS: Mean axial subsidence was 1 mm (±1.4 mm) after 24 months. BMI, diagnosis, gender and implant offset did not influence implant migration on a statistical significant level. Nevertheless, a tendency towards more migration in obese and female patients was observed. CONCLUSION: The evaluated short stem prosthesis showed a migration pattern similar to clinical proven standard straight stem implants. The indication of short-stem prostheses should be critically evaluated in obese and female patients.
dc.identifier.doihttp://dx.doi.org/10.18725/OPARU-3470
dc.identifier.ppn80691324X
dc.identifier.urlhttps://oparu.uni-ulm.de/xmlui/123456789/3497
dc.identifier.urnhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-92698
dc.language.isode
dc.publisherUniversität Ulm
dc.rightsStandard
dc.rights.urihttps://oparu.uni-ulm.de/xmlui/license_v3
dc.subjectFCA
dc.subjectKurzschaft
dc.subject.ddcDDC 610 / Medicine & health
dc.subject.gndEinbildröntgenanalyse
dc.subject.gndEndoprothese
dc.subject.meshProstheses and implants
dc.titleMigrationsanalyse des Fitmore-Kurzschaftes durch die Einzel-Bild-Röntgen-Analyse - Femoral-Component-Analysis-Methode
dc.typeDissertation
uulm.affiliationGeneralMedizinische Fakultät
uulm.bibliographieuulm
uulm.categoryPublikationen
uulm.freischaltungVTS2014-11-20T14:22:29Z
uulm.peerReviewnein
uulm.shelfmarkW: W-H 13.870
uulm.typeDCMIText
uulm.updateStatusURNurl_update_general
uulm.vtsID9269

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
vts_9269_13921.pdf
Size:
3.59 MB
Format:
Adobe Portable Document Format
Description:
72 S.

Collections