<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

The effect of composite attachments on the force and moment systems generated by thermoplastic PET-G aligners during the rotation of a mandibular canine : an in-vitro study

Loading...
Thumbnail Image

Date

2019-09-10

Authors

Mikhaiel, Bishoy

Journal Title

Journal ISSN

Volume Title

Publication type

Document version

Distributor

Universität Ulm

Published in

Abstract

INTRODUCTION: The influence of different composite attachments on the three dimensional force-moment (F/M) components exerted by aligners of different thicknesses during laboratory simulation of mesio- and distorotation of a lower canine was examined. MATERIALS AND METHODS: An acrylic mandibular model with a separated right canine mounted on a hexapod via a 3D F/M sensor was used. Duran+® aligners (Scheu Dental, Germany) of thickness 0.5, 0.625, and 0.75 mm were fabricated on plaster models with the measurement tooth in its neutral position. Three different composite attachment variations were designed on plaster casts and attached to the tooth using a corresponding template aligner. The F/M values were recorded during stepwise mesio- and distorotation of tooth 43 in 1° steps up to ±15°, corresponding to 0.5 mm displacements of the tooth's proximal contacts and the rotational stiffness of each attachment variation was calculated. Each rotation step included removal and reseating of the aligner on the acrylic model. Three aligners of each thickness were produced for each direction of rotation. Each aligner underwent three trial repetitions. RESULTS: The median rotational moments for the 0.5 mm aligner and 15° distorotation of tooth 43 when not applying an attachment was 27.49 Nmm (interquartile range, IQR 1.45 Nmm). The corresponding values for the 0.625 and 0.75 mm aligners were 41.04 Nmm (IQR 5.62 Nmm) and 42.48 Nmm (IQR 2.17 Nmm), respectively. The average rotational moments for distorotation were 15% higher than for mesiorotation (p = 0.01). Applying Canine Rotation Attachment (CRA) during distorotation and Ellipsoid attachment during mesiorotation demonstrated highest average rotational stiffnesses (9.33 Nmm/° and 11.13 Nmm/°, respectively). Relatively high collateral F/M components, namely an intrusive force besides labiolingual and mesiodistal tipping moments varying with each attachment variation were observed. CONCLUSION: To avoid overloading of periodontal structures, derotation of lower canines should be limited to 10° per setup step, leading to rotational moments of about 15 Nmm. Due to their similarity in biomechanical behaviour with 0.75 mm aligners, 0.625 aligners may be omitted from the aligner sequence. Applying the tested attachments increases the resulting rotational moments. Further studies are required to investigate additional attachment modifications and geometries on minimizing collateral F/M components during canine derotation.

Description

Faculties

Medizinische Fakultät

DFG Project uulm

EU Project uulm

Other projects uulm

Citation

Is version of

Has version

Supplement to

Supplemented by

Has erratum

Erratum to

Has Part

Part of

DOI external

DOI external

Institutions

Periodical

Degree Program

DFG Project THU

EU Project THU

Other projects THU

Series

Collections

Endorsement

Review

Supplemented By

Referenced By

Zeitraum:

Creative Commons license

Except where otherwised noted, this item's license is described as Standard