<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Preclassification of broadband and sparse infrared data by multiplicative signal correction approach

Loading...
Thumbnail Image

Date

2022-04-01

Authors

Rehman, Hafeez Ur

Tafintseva, Valeria

Zimmermann, Boris

Solheim, Johanne Heitmann

Virtanen, Vesa

Shaikh, Rubina

Nippolainen, Ervin

Afara, Isaac

Saarakkala, Simo

Rieppo, Lassi

Journal Title

Journal ISSN

Volume Title

Document version

publishedVersion

Distributor

Universität Ulm

Published in

Molecules, 2022

Abstract

Preclassification of raw infrared spectra has often been neglected in scientific literature. Separating spectra of low spectral quality, due to low signal-to-noise ratio, presence of artifacts, and low analyte presence, is crucial for accurate model development. Furthermore, it is very important for sparse data, where it becomes challenging to visually inspect spectra of different natures. Hence, a preclassification approach to separate infrared spectra for sparse data is needed. In this study, we propose a preclassification approach based on Multiplicative Signal Correction (MSC). The MSC approach was applied on human and the bovine knee cartilage broadband Fourier Transform Infrared (FTIR) spectra and on a sparse data subset comprising of only seven wavelengths. The goal of the preclassification was to separate spectra with analyte-rich signals (i.e., cartilage) from spectra with analyte-poor (and high-matrix) signals (i.e., water). The human datasets 1 and 2 contained 814 and 815 spectra, while the bovine dataset contained 396 spectra. A pure water spectrum was used as a reference spectrum in the MSC approach. A threshold for the root mean square error (RMSE) was used to separate cartilage from water spectra for broadband and the sparse spectral data. Additionally, standard noise-to-ratio and principle component analysis were applied on broadband spectra. The fully automated MSC preclassification approach, using water as reference spectrum, performed as well as the manual visual inspection. Moreover, it enabled not only separation of cartilage from water spectra in broadband spectral datasets, but also in sparse datasets where manual visual inspection cannot be applied.

Description

Faculties

Fakultät für Naturwissenschaften

DFG Project uulm

Other projects uulm

Citation

Is version of

Has version

Supplement to

Has erratum

Erratum to

Has Part

Part of

DOI external

DOI external

10.3390/molecules27072298

Institutions

Periodical

Degree Program

DFG Project THU

EU Project THU

Other projects THU

Series

Collections

Endorsement

Review

Supplemented By

Referenced By

Zeitraum:

Creative Commons license

Except where otherwised noted, this item's license is described as CC BY 4.0 International