<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Preclassification of broadband and sparse infrared data by multiplicative signal correction approach

dc.contributor.authorRehman, Hafeez Ur
dc.contributor.authorTafintseva, Valeria
dc.contributor.authorZimmermann, Boris
dc.contributor.authorSolheim, Johanne Heitmann
dc.contributor.authorVirtanen, Vesa
dc.contributor.authorShaikh, Rubina
dc.contributor.authorNippolainen, Ervin
dc.contributor.authorAfara, Isaac
dc.contributor.authorSaarakkala, Simo
dc.contributor.authorRieppo, Lassi
dc.contributor.authorKrebs, Patrick
dc.contributor.authorFomina, Polina
dc.contributor.authorMizaikoff, Boris
dc.contributor.authorKohler, Achim
dc.contributor.editorDe Luca, Michele
dc.contributor.editorRagno, Gaetano
dc.date.accessioned2024-01-19T13:42:05Z
dc.date.available2024-01-19T13:42:05Z
dc.date.issued2022-04-01de
dc.date.updated2022-05-05T15:41:53Z
dc.description.abstractPreclassification of raw infrared spectra has often been neglected in scientific literature. Separating spectra of low spectral quality, due to low signal-to-noise ratio, presence of artifacts, and low analyte presence, is crucial for accurate model development. Furthermore, it is very important for sparse data, where it becomes challenging to visually inspect spectra of different natures. Hence, a preclassification approach to separate infrared spectra for sparse data is needed. In this study, we propose a preclassification approach based on Multiplicative Signal Correction (MSC). The MSC approach was applied on human and the bovine knee cartilage broadband Fourier Transform Infrared (FTIR) spectra and on a sparse data subset comprising of only seven wavelengths. The goal of the preclassification was to separate spectra with analyte-rich signals (i.e., cartilage) from spectra with analyte-poor (and high-matrix) signals (i.e., water). The human datasets 1 and 2 contained 814 and 815 spectra, while the bovine dataset contained 396 spectra. A pure water spectrum was used as a reference spectrum in the MSC approach. A threshold for the root mean square error (RMSE) was used to separate cartilage from water spectra for broadband and the sparse spectral data. Additionally, standard noise-to-ratio and principle component analysis were applied on broadband spectra. The fully automated MSC preclassification approach, using water as reference spectrum, performed as well as the manual visual inspection. Moreover, it enabled not only separation of cartilage from water spectra in broadband spectral datasets, but also in sparse datasets where manual visual inspection cannot be applied.de
dc.description.versionpublishedVersionde
dc.identifier.doihttp://dx.doi.org/10.18725/OPARU-52011
dc.identifier.urlhttps://oparu.uni-ulm.de/xmlui/123456789/52087
dc.identifier.urnhttp://nbn-resolving.de/urn:nbn:de:bsz:289-oparu-52087-3
dc.language.isoende
dc.publisherUniversität Ulm
dc.relation.isSupplementedByhttps://www.mdpi.com/article/10.3390/molecules27072298/s1
dc.relation1.doi10.3390/molecules27072298
dc.rightsCC BY 4.0 Internationalde
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectwater spectrumde
dc.subjectsparse spectrade
dc.subjectquality spectrade
dc.subjectspectral preclassificationde
dc.subjectPCAde
dc.subjectquantum cascade lasersde
dc.subjectOPUSde
dc.subject.ddcDDC 540 / Chemistry & allied sciencesde
dc.subject.ddcDDC 570 / Life sciencesde
dc.subject.gndInfrarot-Spektrumde
dc.subject.lcshInfrared spectrade
dc.titlePreclassification of broadband and sparse infrared data by multiplicative signal correction approachde
dc.typeWissenschaftlicher Artikelde
source.articleNumber2296de
source.identifier.eissn1420-3049de
source.issue7de
source.publisherMDPIde
source.titleMoleculesde
source.volume27de
source.year2022de
uulm.OAGreen Published, gold
uulm.affiliationGeneralFakultät für Naturwissenschaftende
uulm.affiliationSpecificInstitut für Analytische und Bioanalytische Chemiede
uulm.bibliographieuulm
uulm.categoryPublikationen
uulm.identifier.wos000780506400001
uulm.peerReviewjade
uulm.projectEUMIRACLE / Mid-infrared arthroscopy innovative imaging system for real-time clinical in depth examination and diagnosis of degenerative joint diseases / EC / H2020 / 780598de
uulm.typeDCMITextde
uulm.updateStatusURNurn_new

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
molecules-27-02298.pdf
Size:
1.74 MB
Format:
Adobe Portable Document Format

Collections