<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

A modular cage may prevent endplate damage and improve spinal deformity correction

Loading...
Thumbnail Image

Date

2025-03-30

Authors

Jansen, Jan Ulrich

Sciortino, Vincenza

Heuer, Frank

Wilke, Hans-Joachim

Journal Title

Journal ISSN

Volume Title

Document version

publishedVersion

Distributor

Universität Ulm

Published in

Clinical Biomechanics, 2025

Abstract

Background: Anterior lumbar interbody fusion is performed to fuse pathological spinal segments, generally, with a monobloc cage inserted by impact forces. Recently developed three-part modular cages attempt to reduce the impact forces, minimize the damage to the endplates and allow more lordosis angle correction. Methods: Human lumbar motion segments (L2–3, L4–5) were used to simulate the implantation procedure of monobloc vs. modular stand-alone cages (n = 12). After preparing and embedding, a discectomy was performed followed by the two different types of cage implantation. Macroscopic images, microcomputed tomography scans and Artificial-Intelligence-based lordosis angle measurements were conducted and analyzed in the intact and implanted state and endplate damage was evaluated. Findings: The modular and monobloc group had similar impact on three defined damage classes both groups fell into the mid-damage class (29 %); the modular group fell to 13 % in the low-damage class while the monobloc one to 17 % in the high-damage class. Fragmentation appeared more in the monobloc group (71 %), while defects appeared equally. The modular implantation achieved a median lordosis of 21.3° versus 19.5° for the monobloc (P = 0.132) leading to 34 % higher increase for the modular procedure. Interpretation: Endplate damage occurs in both procedures but severe damage like bone fragmentation can be avoided with modular implantation. Bone fragmentation seems to affect and minimize the desired lordosis angle after cage implantation. This in vitro study underlines the need of new implantation procedures to achieve increased lordosis with anterior lumbar interbody fusion to restore the patients sagittal balance successfully.

Description

Faculties

DFG Project uulm

EU Project uulm

Other projects uulm

Citation

Is version of

Has version

Supplement to

Supplemented by

Has erratum

Erratum to

Has Part

Part of

DOI external

DOI external

10.1016/j.clinbiomech.2025.106502

Institutions

Periodical

Degree Program

DFG Project THU

EU Project THU

Other projects THU

Series

Collections

Endorsement

Review

Supplemented By

Referenced By

Zeitraum:

Creative Commons license

Except where otherwised noted, this item's license is described as CC BY 4.0 International