Show simple item record

AuthorBašić, Joannadc.contributor.author
Date of accession2017-05-04T11:38:59Zdc.date.accessioned
Available in OPARU since2017-05-04T11:38:59Zdc.date.available
Year of creation2015dc.date.created
Date of first publication2017-05-04dc.date.issued
AbstractThe orbit and the diseases or injuries which affect it, has been extensively researched in the past century, from all over the continents of the globe. A vast amount of implants (autogeneous, allogeneous and alloplastic) have been inserted on orbital fracture patients, and various treatment results have been published. Titanium has been extensively researched as the pure metal or when mixed with other materials. However the effectiveness of the preformed titanium implants by Synthes (Germany) has not been widely reported except in a few cases and then involving only a small number of patients. Our study focusses on the treatment results of reconstructing 23 unilateral orbital blowout fractures for existing pure orbital floor and/or medial wall fractures using the preformed 3D 'Synthes' orbital implants with a 0.4mm profile. We concluded that these preformed titanium implants produced a very optimum reconstruction of the traumatic orbital floor/orbital floor-medial wall fractures with a relatively very small complication rate.dc.description.abstract
Languageendc.language.iso
PublisherUniversität Ulmdc.publisher
LicenseStandarddc.rights
Link to license texthttps://oparu.uni-ulm.de/xmlui/license_v3dc.rights.uri
Keyword3-D orbital implantsdc.subject
KeywordOrbital floor fracturesdc.subject
KeywordMedial wall fracturesdc.subject
KeywordOcular motility limitationdc.subject
KeywordDouble visiondc.subject
KeywordComputer-assisted navigationdc.subject
Dewey Decimal GroupDDC 610 / Medicine & healthdc.subject.ddc
MeSHOrbital fracturesdc.subject.mesh
MeSHEnophthalmos; Surgerydc.subject.mesh
MeSHExophthalmos; Surgerydc.subject.mesh
MeSHOcular motility disordersdc.subject.mesh
MeSHOrbital implants; Trendsdc.subject.mesh
MeSHDiplopiadc.subject.mesh
TitleA prospective study of the clinical outcomes of orbital floor and medial wall blowout fractures using preformed 3-D implantsdc.title
Resource typeDissertationdc.type
Date of acceptance2016-11-17dcterms.dateAccepted
RefereeSchramm, Alexanderdc.contributor.referee
RefereeHoffmann, Thomasdc.contributor.referee
DOIhttp://dx.doi.org/10.18725/OPARU-4328dc.identifier.doi
PPN887724280dc.identifier.ppn
URNhttp://nbn-resolving.de/urn:nbn:de:bsz:289-oparu-4367-3dc.identifier.urn
GNDAugenhöhledc.subject.gnd
GNDSeptumplastikdc.subject.gnd
GNDNasenscheidewanddc.subject.gnd
GNDEnophthalmiedc.subject.gnd
GNDExophthalmusdc.subject.gnd
GNDAugenbewegungdc.subject.gnd
GNDImplantatdc.subject.gnd
FacultyMedizinische Fakultätuulm.affiliationGeneral
InstitutionBundeswehrkrankenhaus Ulm (BWK)uulm.affiliationSpecific
InstitutionUKU. Klinik für Hals-, Nasen- und Ohrenheilkundeuulm.affiliationSpecific
InstitutionUKU. Klinik für Mund-, Kiefer- und Gesichtschirurgieuulm.affiliationSpecific
Shelfmark print versionW: W-H 15.097uulm.shelfmark
Grantor of degreeMedizinische Fakultätuulm.thesisGrantor
DCMI TypeTextuulm.typeDCMI
TypeErstveröffentlichunguulm.veroeffentlichung
CategoryPublikationenuulm.category
Bibliographyuulmuulm.bibliographie


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record