Show simple item record

AuthorGeyer, Stephaniedc.contributor.author
Date of accession2016-03-15T10:43:04Zdc.date.accessioned
Available in OPARU since2016-03-15T10:43:04Zdc.date.available
Year of creation2013dc.date.created
AbstractBackground: In this study midterm results of an open and modified double-row fixation of the rotator cuff with titanium anchor screws are presented. Material and methods: 2007 237 patients (m 142, f 95, median age: 56,3 years) were operated by one surgeon in this technique. Preoperatively, 2 years and 4,5 years postoperatively a subjective shoulder score (SSG) was evaluated. 5,1 years postoperatively the clinical evaluation with the Constant-Murley-Scores (CS), the Simple-Shoulder-Tests (SST), Gerber’s Shoulder Value and the evaluation with school grades for 131 patients was done. Furthermore the integrity of the cuff was checked with ultrasound. Results: The SSG with follow-up rates of 86, 87 and 83% and the Shoulder Value of Gerber improved significantly from preoperatively to postoperatively (p<0,001). 80 points (min.:18; max.:100) were achieved in the CS, and in SST 11 (min.:2; max.:12) points . The re-tear rate that was evaluated in ultrasound was 7,6% and 17,6% relativ. Conclusion: Open double row cuff repair with titanium screws is a safe technique with a low re-tear rate with comparable clinical results regarding open and arthroscopic procedures. Keywords: rotator cuff repair, double-row, costs, re-tear ratedc.description.abstract
Languagededc.language.iso
PublisherUniversität Ulmdc.publisher
LicenseStandarddc.rights
Link to license texthttps://oparu.uni-ulm.de/xmlui/license_v3dc.rights.uri
KeywordDouble-row Technikdc.subject
KeywordOffene Rotatorenmanschettenrekonstruktiondc.subject
Dewey Decimal GroupDDC 610 / Medicine & healthdc.subject.ddc
MeSHOrthopedic fixation devicesdc.subject.mesh
MeSHOrthopedic procedures; Methodsdc.subject.mesh
MeSHRotator cuff; Surgerydc.subject.mesh
TitleMittelfristige Ergebnisse nach offener Rotatorenmanschettenrekonstruktion in Double-row Technik mit Titanankerschraubedc.title
Resource typeDissertationdc.type
DOIhttp://dx.doi.org/10.18725/OPARU-3797dc.identifier.doi
PPN847529916dc.identifier.ppn
URNhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-99214dc.identifier.urn
GNDRotatorenmanschettedc.subject.gnd
FacultyMedizinische Fakultätuulm.affiliationGeneral
Date of activation2016-02-05T11:38:15Zuulm.freischaltungVTS
Peer reviewneinuulm.peerReview
Shelfmark print versionW: W-H 14.583uulm.shelfmark
DCMI TypeTextuulm.typeDCMI
VTS ID9921uulm.vtsID
CategoryPublikationenuulm.category
Bibliographyuulmuulm.bibliographie


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record