Show simple item record

AuthorBrehmer, Stefaniedc.contributor.author
Date of accession2016-03-15T09:06:38Zdc.date.accessioned
Available in OPARU since2016-03-15T09:06:38Zdc.date.available
Year of creation2012dc.date.created
AbstractAim of this study was the evaluation of the potential of cerebral rheography for non invasive ICP measurement. Rheography is based on heartbeat depending changes of intracranial impedance which is recorded with common ECG electrodes placed frontal, temporal retromastoidal and occipital. A light non remarkable current is delivered by both external electrodes while changes in electrical resistance are messured by thy internal electrodes. Each person has individual basis impedance depending on the blood/cerebrospinal fluid ratio in the cranium. Every heartbeat induces a change in this ratio which can be measured as a change in resistance. The achieved curve was analysed depending on the heartbeat. First safety, reproducibility and applicability were tested by a pre-study with 14 healthy subjects. ICP-changes were induced by body position chances with a tilting table. Afterwards measurements on 23 patients parallel to invasive ICP measurement were performed. An algorithm to analyse the rheogramm was developed by calculating the ascending ratio of the curve. It was observed that the ascending ratio dropped when body position was raised. A good graphic correlation between invasive measured ICP and Rheogramm was seen as well as between both ascending ratios. Further measurements while lumbar infusion testing and alternated PEEP in respirated patients were performed. Rheography is a save, cost-efficient, easy applicable and combinable with other ICU measurement methods. There were seen recording problems especially when ICP became negative or with uncooperative patients.dc.description.abstract
Languagededc.language.iso
PublisherUniversität Ulmdc.publisher
LicenseStandarddc.rights
Link to license texthttps://oparu.uni-ulm.de/xmlui/license_v3dc.rights.uri
KeywordIntracranial compliancedc.subject
KeywordNon-invasive measurementdc.subject
KeywordPlethysmography, impedancedc.subject
Dewey Decimal GroupDDC 610 / Medicine & healthdc.subject.ddc
MeSHIntracranial hypertensiondc.subject.mesh
MeSHIntracranial pressuredc.subject.mesh
TitleWertigkeit der Schädelrheographie zur nicht-invasiven Hirndruckmessungdc.title
Resource typeDissertationdc.type
DOIhttp://dx.doi.org/10.18725/OPARU-2765dc.identifier.doi
PPN731351770dc.identifier.ppn
URNhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-82534dc.identifier.urn
FacultyMedizinische Fakultätuulm.affiliationGeneral
Date of activation2012-11-22T15:31:16Zuulm.freischaltungVTS
Peer reviewneinuulm.peerReview
Shelfmark print versionW: W-H 13.107uulm.shelfmark
DCMI TypeTextuulm.typeDCMI
VTS ID8253uulm.vtsID
CategoryPublikationenuulm.category
Bibliographyuulmuulm.bibliographie


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record