Show simple item record

AuthorFriedrich, Patricia Claudedc.contributor.author
Date of accession2016-03-14T15:22:28Zdc.date.accessioned
Available in OPARU since2016-03-14T15:22:28Zdc.date.available
Year of creation2007dc.date.created
AbstractPurpose: To objectively evaluate the benefit of a contrast medium with high concentration Iodine for Multi-Detector CT Angiography (MDCTA) of the aorta using automatic bolus tracking. - Materials and methods: A total of 100 consecutive MDCTA examinations of the entire aorta were evaluated. All scans were performed on a 40 channel MDCT scanner. A contrast medium with a high Iodine concentration of 400 mg/ml (Imeron 400, Bracco, Milano, Italy) was administered by power injector at a dose of 1.2 ml/kg BW and at a rate of 3.5 ml/sec, followed by a saline chaser. Scanning was initiated by automated bolus tracking with a delay of 6 sec after attaining a measured threshold of 150 HU in the descending aorta. Time-density distributions calculated from the ascending aorta downstream to the common femoral arteries were graded as from poor to excellent based on contrast density, homogeneity, and timing of the scan acquisition. - Results: Evaluated aortic lesions included 23 thoracic and 39 abdominal aneurysms and 30 aortic dissections. The mean (± SD) overall arterial density of MDCTA was 306 ± 66 HU (range: 129 - 476 HU). Averaged arterial contrast density was rated good or better in 92 cases (> 200 HU) while contrast homogeneity was rated good or better in 83 cases. Automatic bolus tracking permitted accurate scanning during peak contrast enhancement in 87 cases. The 13 mistimed examinations comprised 12 MDCTA studies that were started early and one that was started late. In all early scans the contrast density was still considered good or better. - Conclusion: The combination of high concentration contrast medium and automatic bolus tracking allows reliable MDCTA of the entire aorta including the pelvic axis with excellent and homogeneous contrast distribution in a variety of aortic pathologies.dc.description.abstract
Languagededc.language.iso
PublisherUniversität Ulmdc.publisher
LicenseStandard (Fassung vom 03.05.2003)dc.rights
Link to license texthttps://oparu.uni-ulm.de/xmlui/license_v1dc.rights.uri
KeywordAutomatisches Bolus-Trackingdc.subject
Dewey Decimal GroupDDC 610 / Medicine & healthdc.subject.ddc
MeSHAngiographydc.subject.mesh
TitleEvaluierung von hochkonzentriertem jodhaltigem Kontrastmittel in der Multidetektor-Computer-Tomographie der Aorta mit automatischem Bolus-Trackingdc.title
Resource typeDissertationdc.type
DOIhttp://dx.doi.org/10.18725/OPARU-1463dc.identifier.doi
URNhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-64898dc.identifier.urn
GNDAngiographiedc.subject.gnd
GNDComputertomographiedc.subject.gnd
GNDKontrastmitteldc.subject.gnd
FacultyMedizinische Fakultätuulm.affiliationGeneral
Date of activation2008-07-22T16:06:44Zuulm.freischaltungVTS
Peer reviewneinuulm.peerReview
Shelfmark print versionZ: J-H 11.961; W: W-H 11.445uulm.shelfmark
DCMI TypeTextuulm.typeDCMI
VTS-ID6489uulm.vtsID
CategoryPublikationenuulm.category


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record