Show simple item record

AuthorHilscher, Christiandc.contributor.author
Date of accession2016-03-14T15:22:20Zdc.date.accessioned
Available in OPARU since2016-03-14T15:22:20Zdc.date.available
Year of creation2007dc.date.created
AbstractResorbable- versus titanium implants for the treatment of mandibular angle fractures - a comparison of the stability in a biomechanical in vitro examination. Background: The use of semi rigid titanium systems for the treatment of mandibular angle fractures becomes more and more clinical routine. Mostly low profile miniplates (2.0 mm, 1.5 mm) are used for the internal fixation. This investigation should show if resorbable miniplates may be able to provide the same stability as titanium plates. Material and methods: In the present study a biomechanical in vitro model (mandibular strain simulator) is used to examine the stability of different resorbable and titanium plates used for the fixation of a mandibular angle fracture in an artificial mandible (synbone). Three titanium systems (Synthes 2.0, 1.5 and 1.3) and four resorbable systems (Inion CPS 2.5 and 1.5, Lactosorb 2.0, MacroSorb 1.5) have been tested. Results: There have been only small differences between the resorbable and the titanium fixation systems. The Synthes 2.0 titanium plating system has shown the biggest Stability of all systems, followed by Inion 2.5, Lactosorb 2.0, MacroSorb 1.5, Inion 1.5 and Synthes 1.5 and 1.3. Conclusion: In terms of stability of the fixation, the plate-screw-compound and their specific mechanical characteristics, resorbable miniplates provide nearly the same stability as titanium miniplates. To reach an equal stability as a titanium miniplate, a slightly bigger resorbable plating system should be used.dc.description.abstract
Languagededc.language.iso
PublisherUniversität Ulmdc.publisher
LicenseStandard (Fassung vom 03.05.2003)dc.rights
Link to license texthttps://oparu.uni-ulm.de/xmlui/license_v1dc.rights.uri
KeywordKieferwinkeldc.subject
Keywordresorbierbardc.subject
KeywordStabilitätdc.subject
KeywordTitanosteosynthesesystemedc.subject
KeywordUnterkiefersimulatordc.subject
Dewey Decimal GroupDDC 610 / Medicine & healthdc.subject.ddc
MeSHMandibular fractures. Therapydc.subject.mesh
TitleResorbierbare- versus Titanimplantate bei Frakturen im Kieferwinkelbereich - Vergleichsstudie zur Stabilität von Osteosynthesen im biomechanischen Modellversuchdc.title
Resource typeDissertationdc.type
DOIhttp://dx.doi.org/10.18725/OPARU-1424dc.identifier.doi
URNhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-64255dc.identifier.urn
GNDOsteosynthesedc.subject.gnd
FacultyMedizinische Fakultätuulm.affiliationGeneral
Date of activation2008-06-24T11:56:42Zuulm.freischaltungVTS
Peer reviewneinuulm.peerReview
Shelfmark print versionZ: J-H 11.855; W: W-H 11.343uulm.shelfmark
DCMI TypeTextuulm.typeDCMI
VTS-ID6425uulm.vtsID
CategoryPublikationenuulm.category


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record