Zur Kurzanzeige

AutorHilscher, Christiandc.contributor.author
Aufnahmedatum2016-03-14T15:22:20Zdc.date.accessioned
In OPARU verfügbar seit2016-03-14T15:22:20Zdc.date.available
Jahr der Erstellung2007dc.date.created
ZusammenfassungResorbable- versus titanium implants for the treatment of mandibular angle fractures - a comparison of the stability in a biomechanical in vitro examination. Background: The use of semi rigid titanium systems for the treatment of mandibular angle fractures becomes more and more clinical routine. Mostly low profile miniplates (2.0 mm, 1.5 mm) are used for the internal fixation. This investigation should show if resorbable miniplates may be able to provide the same stability as titanium plates. Material and methods: In the present study a biomechanical in vitro model (mandibular strain simulator) is used to examine the stability of different resorbable and titanium plates used for the fixation of a mandibular angle fracture in an artificial mandible (synbone). Three titanium systems (Synthes 2.0, 1.5 and 1.3) and four resorbable systems (Inion CPS 2.5 and 1.5, Lactosorb 2.0, MacroSorb 1.5) have been tested. Results: There have been only small differences between the resorbable and the titanium fixation systems. The Synthes 2.0 titanium plating system has shown the biggest Stability of all systems, followed by Inion 2.5, Lactosorb 2.0, MacroSorb 1.5, Inion 1.5 and Synthes 1.5 and 1.3. Conclusion: In terms of stability of the fixation, the plate-screw-compound and their specific mechanical characteristics, resorbable miniplates provide nearly the same stability as titanium miniplates. To reach an equal stability as a titanium miniplate, a slightly bigger resorbable plating system should be used.dc.description.abstract
Sprachededc.language.iso
Verbreitende StelleUniversität Ulmdc.publisher
LizenzStandard (Fassung vom 03.05.2003)dc.rights
Link zum Lizenztexthttps://oparu.uni-ulm.de/xmlui/license_v1dc.rights.uri
SchlagwortKieferwinkeldc.subject
Schlagwortresorbierbardc.subject
SchlagwortStabilitätdc.subject
SchlagwortTitanosteosynthesesystemedc.subject
SchlagwortUnterkiefersimulatordc.subject
DDC-SachgruppeDDC 610 / Medicine & healthdc.subject.ddc
MeSHMandibular fractures. Therapydc.subject.mesh
TitelResorbierbare- versus Titanimplantate bei Frakturen im Kieferwinkelbereich - Vergleichsstudie zur Stabilität von Osteosynthesen im biomechanischen Modellversuchdc.title
RessourcentypDissertationdc.type
DOIhttp://dx.doi.org/10.18725/OPARU-1424dc.identifier.doi
URNhttp://nbn-resolving.de/urn:nbn:de:bsz:289-vts-64255dc.identifier.urn
GNDOsteosynthesedc.subject.gnd
FakultätMedizinische Fakultätuulm.affiliationGeneral
Datum der Freischaltung2008-06-24T11:56:42Zuulm.freischaltungVTS
Peer-Reviewneinuulm.peerReview
Signatur DruckexemplarZ: J-H 11.855; W: W-H 11.343uulm.shelfmark
DCMI MedientypTextuulm.typeDCMI
VTS-ID6425uulm.vtsID
KategoriePublikationenuulm.category


Dateien zu dieser Ressource

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige