<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">

Laser-irradiating infrared attenuated total reflection spectroscopy of articular cartilage: Potential and challenges for diagnosing osteoarthritis

Loading...
Thumbnail Image

Date

2024-04-10

Authors

Krebs, Patrick

Nägele, M.

Fomina, Polina

Virtanen, V.

Nippolainen, E.

Saikh, R.

Afara, I. O.

Töyräs, J.

Usenov, I.

Sakharova, T.

Journal Title

Journal ISSN

Volume Title

Document version

publishedVersion

Distributor

Universität Ulm

Published in

Osteoarthritis and Cartilage Open, 2024

Abstract

Objective A prototype infrared attenuated total reflection (IR-ATR) laser spectroscopic system designed for in vivo classification of human cartilage tissue according to its histological health status during arthroscopic surgery is presented. Prior to real-world in vivo applications, this so-called osteoarthritis (OA) scanner has been tested at in vitro conditions revealing the challenges associated with complex sample matrices and the accordingly obtained sparse spectral datasets. Methods In vitro studies on human knee cartilage samples at different contact pressures (i.e., 0.2–0.5 ​MPa) allowed recording cartilage degeneration characteristic IR signatures comparable to in vivo conditions with high temporal resolution. Afterwards, the cartilage samples were assessed based on the clinically acknowledged osteoarthritis cartilage histopathology assessment (OARSI) system and correlated with the obtained sparse IR data. Results Amide and carbohydrate signal behavior was observed to be almost identical between the obtained sparse IR data and previously measured FTIR data used for sparse partial least squares discriminant analysis (SPLSDA) to identify the spectral regions relevant to cartilage condition. Contact pressures between 0.3 and 0.4 ​MPa seem to provide the best sparse IR spectra for cylindrical (d ​= ​3 ​mm) probe tips. Conclusion Laser-irradiating IR-ATR spectroscopy is a promising analytical technique for future arthroscopic applications to differentiate healthy and osteoarthritic cartilage tissue. However, this study also revealed that the flexible connection between the laser-based analyzer and the arthroscopic ATR-probe via IR-transparent fiberoptic cables may affect the robustness of the obtained IR data and requires further improvements.

Description

Faculties

Fakultät für Naturwissenschaften

DFG Project uulm

EU Project uulm

Other projects uulm

Citation

Is version of

Has version

Supplement to

Has erratum

Erratum to

Has Part

Part of

DOI external

DOI external

10.1016/j.ocarto.2024.100466

Institutions

Periodical

Degree Program

DFG Project THU

EU Project THU

Other projects THU

Series

Collections

Endorsement

Review

Supplemented By

Referenced By

Zeitraum:

Creative Commons license

Except where otherwised noted, this item's license is described as CC BY-NC-ND 4.0 International